What measures should be taken when there is a temporary power outage during the operation of the electrical incubator?

According to the power outage season, the length of the power outage is a regular power outage or an occasional power outage, and the specific conditions of the embryonic age of eggs in the incubator take corresponding measures.
(1) In early spring, the temperature is low, and indoor heating equipment is not added. The room temperature is more than just (5 to 10°C). At this time, the inlet and outlet holes of the incubator are generally closed. If the power outage time is within 4 hours, you may not need to take any measures. If the power outage is long, heating equipment should be added indoors to quickly increase the room temperature to 32°C. If there are also embryonic eggs that are hatched, but the number is not large, the treatment is the same as above. If the number of eggs in the hatching box is large, care must be taken to prevent overheating of the embryonic eggs on the central part and on the top, and when the temperature of the eggs is hot, one can adjust the dial.
(2) If the temperature exceeds 25°C and the embryo temperature of the eggs in the electric incubator is within 10 days, no measures may be taken during the power failure. When the embryo age exceeds 13 days, the door should be opened first to reduce the temperature inside the machine. It is estimated that After several layers of egg temperature drop 2-3°C (depending on the age of the embryo), close the door and check the egg temperature on top of the egg every 2 hours. If it is a hatching box, keep it warm. The opening time of the internal door should be extended. After it is lowered by more than 3 °C, the door is closed. After checking the temperature of the upper layer of eggs every one hour, if there is a trend of overheating, adjust the plate and pay special attention to preventing the egg temperature at the center. Super high.
(3) When the temperature exceeds 30°C, the machine may not take any measures if it is an early egg. If it is a medium- or late-stage egg, the door must be opened (the outlet and the air inlet were originally opened) and the internal temperature Drop it below 35°C, and then close the door (mid-term egg) or the door is tight, leave a late-season egg, and check the egg temperature on the top several layers per hour. If there is a long period of power outage, or if the power outage is not long, but regular short-term power outages (such as 2 to 3 hours) almost every day, you have to adjust the disk every day or every 2 days.
In order to compensate for the low temperature caused by daily power outages (especially in areas with high power outages), the normal incubation temperature should be about 0.28°C higher than the normal temperature standard used. In this way, despite a short-term power outage every day, chick embryos can be guaranteed to hatch on the 21st day.