China Manufacturer Contec Fingertip Pulse Oximeter

Model NO.: CMS50D
Certificate: Ce&FDA
Color: Blue,Light Blue,Yellow,Pink,Black,White
Model: Cms50d
Screen: OLED
Trademark: CONTEC
Transport Package: Carton
Specification: 110*70*40(mm)
Origin: Hebei, China
HS Code: 9018909011
     China Manufacturer CONTEC Fingertip Pulse Oximeter
                             Model:CMS50D

 

Introduction of fingertip pulse oximeter

Principle of the CMS50D Pulse Oximeter is as follows: Photoelectric Oxyhemoglobin Inspection Technology is adopted in accordance with Capacity Pulse Scanning & Recording Technology,the Pulse Oximeter can be used in measuring the pulse oxygen saturation and pulse rate through finger.The product is suitable for being used in family, hospital, oxygen bar, community healthcare, physical care in sports (It can be used before or after doing sports, and it is not recommended to use the device during the process of having sport) and etc.


Major Features

1)SpO2 value display
2)Pulse rate value display, bar graph display
3)Pulse waveform display
4)Screen brightness can be changed
5)Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage,Automatically power off function: when the device is under the state of measuring interface . it will automatically power off within 5 seconds if the finger falls out of probe
6)Display format can be saved after power off

Main performance
Desription  Fingertip Pulse Oximeter (oximetry)
Display Mode 0.96"Dual-color OLED display(blue and yellow)
Screen Resolution: 128*64 128*64
SpO2 Measuring Range
Accuracy
0%~100%, (the resolution is 1%).
70%~100%: ±2% ,Below 70% unspecified.
PR Measuring Range
Accuracy
30bpm~250bpm, (the resolution is 1bpm)
±2bpm or ±2% (select larger)
Measurement Performance in Weak Filling Condition SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).
Resistance to surrounding light The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%.
Power Consumption less than 30mA
Voltage DC 2.6V~3.6V
Power Supply 1.5V (AAA size) alkaline batteries × 2
Battery working hour The minimum continually work time is 20 hours, theoretical number is 36 hours.
Safety Type Interior Battery, BF Type
Dimension 57(L) × 31(W) × 32(H) mm
Weight About 50g 

Accessories

 

1)a hanging rope
2)a user manual

Optional:1)Black Carry bag
        2)Battery
        3)Silicon Rubber Case
 

Certificate:

CE/FDA

Warehouse

China/USA
China Manufacturer Contec Fingertip Pulse Oximeter
 

Red Wolfberry

Organic Red Dried Jujube,Dried Grapes Crispy,Factory Dried Goji Berry

Black wolfberry, Red dates Co.,Ltd , http://www.chwolfberry.com